Upgrading an existing structure into a high-performing cannabis greenhouse can multiply yield, stabilize quality, and lower $/lb—but only if the retrofit sequence, power, and controls are engineered correctly. This guide distills proven approaches for light deprivation, heating, and dehumidification, then translates them into lender-ready TI scopes, operating models, and event-based timelines you can put in an LOI or construction contract. When you’re ready to evaluate inventory, shortlist assets on 420 Property—start with greenhouses for sale or greenhouses for lease to benchmark delivered specs, power, and pricing.

Why retrofits beat starting from scratch

Well-planned retrofits leverage existing glazing, site utilities, and foundations, compressing schedules and capex relative to new builds. For cannabis greenhouses, every dollar you save in structural work can be shifted into the three systems that protect quality and throughput: blackout (photoperiod), thermal energy, and moisture control. The result is more predictable harvest windows, tighter cannabinoid/terpene profiles, and process stability that shows up in SDE/EBITDA and DSCR.

Core Design Targets for a Cannabis Greenhouse (What Success Looks Like)

  • Photoperiod accuracy: Repeatable 12/12 periods with <1 lux stray light at canopy during dark cycle; automated failsafes.
  • Thermal stability: Tight supply air and leaf temperature control across seasons; thermal screens to reduce night losses and day gains.
  • Moisture balance: Dehumidification sized to latent loads (transpiration + irrigation) with VPD-aware setpoints and night-cycle control.
  • Air distribution: Homogeneous mixing—no cold corners or wet walls—via HAF (horizontal airflow) and destratification.
  • Controls & sequencing: One BMS/PLC layer orchestrating curtains, heat, venting, dehu, CO₂, and alarms—plus power monitoring to prevent nuisance trips.
  • Compliance readiness: Zoning/CUP alignment, life-safety, gas/boiler permits, and odor mitigation documented for the AHJ; TI schedule keyed to approvals.

Use those targets to reverse-engineer your scope, budget, and risk controls.

Part 1 — Light Deprivation (Blackout) That Works Every Day of the Year

System Choices

  • Internal blackout curtains (most common): Dual-rail or single-rail systems with light-tight overlaps, side seals, and end-wall pockets.
  • External shade/blackout: Good for heat rejection but higher wind/maintenance exposure; often paired with internal thermal screens.
  • Hybrid: Daytime external shade + internal blackout for photoperiod and thermal retention.

Engineering Must-Haves

  • Blackout integrity: Overlaps, brush seals, and end-wall treatments that maintain <1 lux at canopy; test with a meter on a moonless night.
  • Drive & controls: Redundant motors and position feedback (open/close %), limit switches, and UPS/backup power sequences so an outage doesn’t torch a crop schedule.
  • Condensation management: Curtain fabric choice (porosity/condensation resistance) and guttering to prevent drip on canopy during cool nights.
  • Integration: Curtain logic coordinated with heat, vents, dehu, and CO₂ so you don’t trap humidity or starve plants of enrichment.

Light-Dep Commissioning Checklist

  • Curtain speed and torque (full travel without stall).
  • Seal integrity under wind load (smoke-stick test at seams).
  • Light meter validation (<1 lux) at multiple canopy points.
  • Alarm points (fail to open/close within time window) and manual override procedures.

Valuation tie-in: Reliable light-dep converts calendar into predictable harvest windows—underwriting loves that. It tightens your QoE assumptions and makes lender coverage more defensible.

Part 2 — Heating & Thermal Strategy (Boilers, Unit Heaters, Radiant)

Common Approaches

  • Hydronic boilers + fin-tube/radiant benches: Even heat, strong latent support when paired with dehu, excellent for shoulder seasons.
  • Direct-fired or sealed-combustion unit heaters: Lower capex; ensure combustion air and flueing meet code to avoid CO/NOx issues.
  • Under-bench radiant (hot water): Targets root-zone temps, improves growth rates, and can lower room-setpoints.

Design Inputs to Get Right

  • Load calc: Size to design day/night conditions using local weather files; separate sensible vs. latent implications so dehu isn’t under-sized.
  • Air distribution: HAF fans to break stratification; verify throw patterns and avoid short-circuiting across the canopy.
  • Thermal screens: Daytime shading and nighttime energy retention; can reduce boiler runtime significantly in cold climates.
  • Fuel & tariffs: Natural gas vs. propane availability and rates; add 10–20% headroom for future expansions or colder winters.
  • Controls: PID loops for supply air, leaf-surface temp feedback (IR sensors), curtain interlocks, frost protection logic.

Heating Commissioning Checklist

  • Boiler safety controls (limit, low-water cutoff, gas trains) and start-up documents.
  • Balancing of circuits (even ∆T across fin-tubes/benches).
  • Alarms to BMS (loss of flame, low gas, freeze risks).
  • Seasonal setpoint schedules verified in trend logs.

Valuation tie-in: Lower thermal volatility reduces crop loss risk and labor hours on “fire drills”—it shows up in margin stability and better EBITDA quality.

Part 3 — Dehumidification (Latent Load Is the Silent Yield Killer)

Options and When to Use Them

  • DX (refrigeration) dehumidifiers: Fast response, straightforward install; size for peak night transpiration plus irrigation events.
  • Desiccant systems: Useful for cold climates or when very low dew points are needed; confirm reactivation heat source.
  • Ventilation + heat recovery: Economical in mild/dry climates; consider enthalpy wheels or plate exchangers and odor control.

Sizing Method (Practical)

  1. Estimate peak transpiration per m² canopy for your genetics and plant counts (conservative assumptions).
  2. Add irrigation/evaporation events (nighttime sprays).
  3. Convert lb/hr moisture to pints/hr or kg/hr and match to equipment capacity at expected room temp/RH (not at AHRI lab points).
  4. Add 15–25% headroom for harvest/trim periods.

VPD-Aware Control

  • Target vapor pressure deficit ranges appropriate to growth stage; orchestrate dehu with heat so you don’t chase your tail (cold air + high RH).
  • Coordinate blackout timing: when curtains close, dehu should pre-stage to avoid spikes as transpiration continues while ventilation stops.

Dehu Commissioning Checklist

  • Condensate management (floor drains or sump), GFCI protection, and pan heater controls (cold climates).
  • Noise and vibration isolation (for worker comfort and fixture longevity).
  • Trend logs: RH spikes after irrigation and after curtain close should be brief and bounded.

Valuation tie-in: Mold outbreaks and botrytis are value killers. Right-sized dehu reduces crop loss and insurance claims, protecting DSCR and exit multiples.

Airflow & Mixing: The “Fourth System” Most Teams Underspec

  • HAF network: Sized for 2–4 air turns/minute without excessive leaf flutter; align rows to avoid dead zones.
  • Destratification fans: Cut temperature gradients and improve dehu efficiency.
  • Ducted distribution (retrofit greenhouses): Consider sock duct or gentle-throw nozzles to wash the canopy evenly.
  • Filtration and odor: Pre-filters before coils; activated carbon or other odor capture per local rule.

Controls, Power, and Alarms (Where Projects Win or Lose)

  • One brain: A single BMS/PLC to sequence curtains, heat, vents, dehu, CO₂, fans, and alarms.
  • Power quality: Dedicated circuits, selective coordination on breakers, soft-starts/VFDs to limit inrush, and surge suppression on control boards.
  • Alarming: SMS/email for high temp, low temp, high RH, blackout failure, gas leak, loss of flame, and utility events.
  • Data retention: 13-week rolling trends minimum; auditors and buyers will ask.

Compliance, Permitting, and TI Language (Protect Schedule and Coverage)

  • Zoning/CUP: Confirm cannabis use is permitted; map buffers; extract conditions (odor, lighting spill, hours, security). Tie rent commencement to CUP final and appeal window closure.
  • Mechanical/electrical permits: Boilers, gas piping, flueing; electrical service upgrades; structural attachments for curtains and fans.
  • Odor & wastewater: Where required, document systems and sampling points.
  • Fire/Life Safety: Egress, emergency power for blackout, and alarm reporting.

Event-Based Lease Clauses (copy/paste):

  • “Base rent commences the later of (i) issuance of building and fire finals covering blackout, heating, and dehumidification systems and (ii) permanent electric service with utility ‘permission to operate.’”
  • “TI allowance payable against stamped drawings, inspections, and lien releases; retainage released upon commissioning acceptance tests.”
  • “Outside date aligned to hearing calendars and utility energization; if missed for reasons outside Tenant’s control, abatement extends or Tenant may terminate.”

Budgeting, ROI, and Lender-Ready Modeling

TI Scope Buckets (Who Pays for What)

  • Landlord (base-building TI): Structural attachments (curtain trusses/rails), switchgear and feeders, roof penetrations, boiler room shell, odor shafts.
  • Tenant (process TI): Curtain fabric/motors, dehumidifiers, HAF fans, benches/irrigation, controls, CO₂, and commissioning.

ROI Framework

  • Revenue lift: More harvests/year via reliable light-dep; improved category mix due to quality deltas.
  • OPEX savings: Thermal screens (fuel), targeted dehu vs. over-venting (heating penalty), better labor efficiency.
  • Risk reduction: Lower crop loss probability; smoother compliance inspections.

Model notes: Present base and downside cases; keep add-backs conservative; show rent and debt service start dates as events, not calendar guesses. A clear bridge from TI → uptime → yield → EBITDA reads cleanly in QoE and supports lower cap rates at exit.

Phased Retrofit Timeline (90–180 Days, Realistically Sequenced)

  1. Discovery (Weeks 0–3): Structural review; power audit; utility coordination; permit strategy; CUP conditions.
  2. Design (Weeks 2–6): Curtain shop drawings; boiler/dehu selections; controls I/O list; odor/wastewater.
  3. Permitting (Weeks 4–10+): Submit MEP; structural attachments; schedule special inspections.
  4. Procurement (Weeks 4–12): Long-lead motors, fabric, boilers, dehu, switchgear.
  5. Install (Weeks 8–16): Structural steel and rails first; power/distribution; hydronic piping; set dehu and fans.
  6. Controls & Commissioning (Weeks 14–18): Curtain motion/limits; heating balance; VPD sequences; alarm testing; data logging.
  7. Stabilization (Weeks 18–20): First blackout cycle under supervision; adjust setpoints from trend data.

If your local approvals or utility lead times extend beyond your target, align lease commencement and lender draw schedules accordingly.

Common Retrofit Pitfalls—and How to Avoid Them

  • Undersized dehu: Sizing to “lab ratings” rather than room conditions; always use capacity at your operating temp/RH.
  • Curtain light leaks: Skipping end-wall sealing and brush overlaps.
  • Short-circuiting airflow: Mounting HAF where throw meets obstruction; CAD the airstreams.
  • Combustion safety gaps: No combustion air for unit heaters; missing CO/NOx monitoring in tight envelopes.
  • Controls fragmentation: Separate thermostats/timers across systems; insist on one coordinated controller.
  • No event-based paper: Rent starts before utility PTO; TI funds released without commissioning—avoid both.

How to Use 420 Property to Source or Exit Efficiently

  • Benchmark delivered specs: Filter greenhouses for sale by power (kVA), curtain readiness, and existing hydronic/dehu.
  • Model lease-vs-buy: If capex is the limiter, evaluate greenhouses for lease with landlord-funded base-building TI.
  • List with certainty: Sellers: publish one-lines, power letters, curtain photos, and dehu tonnage; buyers pay a premium for proven uptime.
  • Create optionality: Keep two shortlisted assets through LOI; permitting surprises happen—avoid schedule traps.

Retrofit for repeatability, not just yield. Engineer blackout, heating, and dehumidification as a single system, orchestrated by one controller and protected by event-based lease language. Then capitalize on that certainty: compare for sale greenhouse listings and for lease options on 420 Property to move from design intent to an asset that closes—and grows—on schedule.